Product

Related

Floorgard Primer 903
Floorgard Primer 903 is a two part, low viscosity, epoxy resin system to which Fillers can be added to produce epoxy mortars having a variety of consistencies. Floorgard Primer 903 also forms part of the range as priming & coating system.

USES & ADVANTAGES
For combining with selected fillers and aggregates to produce epoxy mortars of various consistencies. Also used as supplied, or with selected filler additions to produce bolt or starter-bar grouts, and as a priming and coating system with some products.
Advantages include:
• Early development of initial hardness, minimises maintenance disruption.
• Unaffected by a wide range of acids, alkalis and industrial chemicals.
• 3 to 4 times stronger than typical concrete.
• Excellent resistance to abrasion and impact.
• Versatile mixing ratios.
A variety of consistencies can be obtained when Fillers are used in conjunction with Floorgard Primer 903, contact Cormix for details on mix designs.
The following results were obtained at a temperature of 20oC unless otherwise specified.
Pot Life : 40 minutes
The pot life quoted refers to the resin system without the addition of fillers. This value will increase as filler is added to the mixed product, with temperature decreases, or if the mixed product is poured in thin layers.
Initial Hardness:         3-5 hours
Full Cure:                    7 days
Below 20oC the curing time will be increased
Min. application temp.:     5oC
Max. service temp.: 60oC
Specific Gravity (A+B mixed):1.08 kg/L.

All grease, oil, chemical contamination, dust, laitance, and loose concrete must be removed by scabbling or light bush hammering to provide a sound substrate. Steel surfaces should be grit blasted to white metal. Surfaces which show any traces of oil must be degreased with a chemical degreaser prior to grit blasting.

PRIMING
For maximum adhesion of heavily filled mortars, etc.,the surfaces to be treated should be primed by applying a coat of unfilled Floorgard Primer 903 before placing the mortar.

MIXING
Mixing Ratio: A:B : 100 : 58 (by weight)
Typical mix design by volume.
Fluid grout
2 parts resin : 1 part hardener : 3 parts filler
Fluid paste
2 parts resin : 1 part hardener : 6 parts filler
Stiff paste
2 parts resin : 1 part hardener : 9 parts filler

 

Cormix Cleaner contains volitile organic solvents.

Floorgard Primer 903
contains epoxy resins and curatives. Some people are sensitive to resins, hardeners and solvents. Avoid contact with skin and eyes and avoid breathing vapour. Use only in well ventilated areas away from heat sparks or naked flames. Wear suitable protective clothing, gloves and eye protection when mixing or using. If poisoning occurs, contact a doctor. If swallowed, do NOT induce vomiting - giving a glass of water. If in eyes, hold eyes open, flush with water for at lease 15 minutes and see a doctor. If skin contact occurs, remove contaminated clothing and wash skin thoroughly with soap and water.


Material Safety Data Sheets (MSDS) are available on request from Cormix International. Read the MSDS and product data sheet carefully before using any product